Warning: count(): Parameter must be an array or an object that implements Countable in /var/www/u2258409/data/www/radiohill.net/wp-content/plugins/formcraft3/formcraft-main.php on line 4926
RH6133-500W

The RH6133 is a solid state, cost effective, broadband power amplifier designed to meet the new standards of software reprogrammable radios to satisfy the performance required in the use of HF radios in modern, digital communication systems.

The RH6133 has proven performance used as a standard RF amplification module. The RF Amplifier/Power Supply is a self-contained unit suitable for tabletop or 19” rack installation.

Broadband RF amplification with the complete elimination of tunable elements gives the family’s components the frequency agility characteristics required by ALE (Automatic Link Establishment) operation over the HF band.

The main features of the amplifier are:

  • Built-in controller
  • LCD monitor
  • 2 –levels overheat protection
  • Short/open output protection
  • Continuous operational cycle at full output power
  • High reliability in harsh environment

The RH6133 capable to be matched with various HF radios: MICOM-2/3, CODAN NGT, Barret 2050 and later, ICOM. Other models can be matched by customer’s request.

6133 rh6133-500w-RH6133-500W-PRODUCTS HF

Technical specifications

Operating Frequency range: 1.6-30 MHz
Output Power:

in SSB mode

in CW mode

peak — 500 W

average — 500 W

Gain: 14 dB
Gain flatness in frequency range ±1 dB
Input power level 20 W
Intermodulation better than –31 dB (ref to any tone)
Non-harmonic components: better than – 60dB
components: better than – 50dB is
Harmonic components: provided with 6-bands switchable filter

at frequency bands:

1.6-2.55 MHz

2.55-4.1 MHz

4.1-6.8 MHz

6.8-11.3 MHz

11.3-18 MHz

18-30 MHz

Input/output impedance: 50 Ω
VSWR 2:1 – 5:1
Operation with unmatched load: Output power is reduced:

240W at VSWR=2.0

180W at VSWR=3.0

160W at VSWR=4.0

80W at VSWR=5.0 autonomous protection at short or open output

Turning on time 3 s
Tx/Rx switching time 15 ms
Rx/Tx switching time 15 ms
Switching between any harmonic filters 15 ms
Cooling system: forced air cooling
Over heat protection: Cooling system automatic control, 2-level protection.
Primary Power: 90-250 VAC, 47-63Hz
Power consumption: Less than 1300 W.
Duty cycle: Continuous, with forced air cooling
Operation temperature range -10 to +50 ºC
Dimensions: 482(W) ×177(H) ×624(D) mm
Weight: 15 kg